 PMID:29675919  

Therapy and Outcome of Staphylococcus aureus Infections of Intracorporeal Ventricular Assist Devices.

Miquel B Ekkelenkamp | Mats T Vervoorn | Jumamurat R Bayjanov | Ad C Fluit | Barry J Benaissa-Trouw | Faiz Z Ramjankhan
Artificial organs | 2018

Infection of the driveline or pump pocket is a common complication in patients with ventricular assist devices (VADs) and Staphylococcus aureus is the main pathogen causing such infections. Limited evidence is currently available to guide the choice of antibiotic therapy and the duration of treatment in these patients. Patients at the University Medical Center Utrecht who developed a VAD-related S. aureus infection between 2007 and 2016 were retrospectively assessed. Blood culture isolates were typed by whole genome sequencing to differentiate between relapses and reinfections, and to determine whether antibiotic therapy had led to acquisition of resistance mutations. Twenty-eight patients had S. aureus VAD infections. Ten of these patients also suffered S. aureus bacteremia. Discontinuation of antibiotic therapy was followed by relapse in 50% of the patients without prior S. aureus bacteremia and in 80% of patients with bacteremia. Oral cephalexin could ultimately suppress the infection for the duration of follow-up in 8/8 patients without S. aureus bacteremia and in 3/6 patients with S. aureus bacteremia. Clindamycin failed as suppressive therapy in 4/4 patients. Cephalexin appears an adequate choice for antibiotic suppression of VAD infections with methicillin-susceptible S. aureus. In patients without systemic symptoms, it may be justified to attempt to stop therapy after treatment of the acute infection, but antibiotic suppression until heart transplant seems indicated in patients with S. aureus bacteremia.

Pubmed ID: 29675919

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Prokka (tool)

RRID:SCR_014732

THIS RESOURCE IS NO LONGER IN SERVICE. Documented on February 28,2023. Software tool for the rapid annotation of prokaryotic genomes. It produces GFF3, GBK and SQN files that are ready for editing in Sequin and ultimately submitted to Genbank/DDJB/ENA. A typical 4 Mbp genome can be fully annotated in less than 10 minutes on a quad-core computer, and scales well to 32 core SMP systems.

View all literature mentions