Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

 PMID:29403892  

Simultaneous determination of ezetimibe and simvastatin in rat plasma by stable-isotope dilution LC-ESI-MS/MS and its application to a pharmacokinetic study.

Sireesha R Karanam | Prakash Katakam | Babu R Chandu | Nagiat T Hwisa | Shanta K Adiki
Journal of pharmaceutical analysis | 2014

A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed for simultaneous quantification of ezetimibe and simvastatin in rat plasma. The deuterium isotopes: ezetimibe d4 and simvastatin d6 were used as internal standards for ezetimibe and simvastatin, respectively. MS/MS detection involved a switch of electron spray ionization mode from negative to positive at retention time 3.01 min. Samples were extracted from plasma by liquid-liquid extraction using tertiary butyl methyl ether. Chromatographic separation was achieved with Agilent Eclipse XBD-C18 column using mobile phase that consisted of a mixture of ammonium acetate (pH4.5; 10 mM)-acetonitrile (25:75 v/v). The method was linear and validated over the concentration range of 0.2-40.0 ng/mL for simvastatin and 0.05-15.0 ng/mL for ezetimibe. The transitions selected were m/z 408.3→271.1 and m/z 412.0→275.10 for ezetimibe and ezetimibe d4, and m/z 419.30→285.20 and m/z 425.40→199.20 for simvastatin and simvastatin d6. Intra- and inter-batch precisions for ezetimibe were 1.6-14.8% and 2.1-13.4%; and for simvastatin 0.94-9.56% and 0.79-12%, respectively. The proposed method was sensitive, selective, precise and accurate for the quantification of ezetimibe and simvastatin simultaneously in rat plasma. The method was successfully applied to a pharmacokinetic study by oral co-administration of ezetimibe and simvastatin in SD rats.

Pubmed ID: 29403892

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


SD (tool)

RRID:RGD_70508

Rattus norvegicus with name SD from RGD.

View all literature mentions