Description: The list of current human performers that are actually involved or responsible for performing the Workitem. Zero or more items may be included in this sequence. Note: Initially this list will be empty.
Preferred ID: DICOM:0040_4035 Type: term ID# ILX:0100295 Score: 0
Description: Position of Beam Stopper during beam administration.
Preferred ID: DICOM:3008_0230 Type: term ID# ILX:0101156 Score: 0
Description: Motion characteristic of Beam.
Preferred ID: DICOM:300A_00C4 Type: term ID# ILX:0101157 Score: 0
Description: Sequence of Brachy Accessory Devices associated with current Application Setup.
Preferred ID: DICOM:300A_0260 Type: term ID# ILX:0101416 Score: 0
Description: Type of Brachy Accessory Device.
Preferred ID: DICOM:300A_0264 Type: term ID# ILX:0101417 Score: 0
Description: The compression force applied to the body part during exposure, measured in Newtons.
Preferred ID: DICOM:0018_11A2 Type: term ID# ILX:0102442 Score: 0
Description: Axis value in degrees
Preferred ID: DICOM:0022_0009 Type: term ID# ILX:0102741 Score: 0
Description: Offset time in mSec that the detector becomes active after the X-Ray beam is turned on during acquisition of this image. May be negative.
Preferred ID: DICOM:0018_7016 Type: term ID# ILX:0103133 Score: 0
Description: Offset of the TLHC of a rectangle circumscribing the active detector area from the TLHC of a rectangle circumscribing the physical detector area, measured in physical detector pixels as a row offset followed by a column offset.
Preferred ID: DICOM:0018_7028 Type: term ID# ILX:0103135 Score: 0
Description: Sequence of Items that describe the detectors used.The number of items shall be equal to Number of Detectors (0054,0021). The first item corresponds to frames with value of 1 in Detector Vector (0054,0020), the second item with value 2, etc.
Preferred ID: DICOM:0054_0022 Type: term ID# ILX:0103146 Score: 0
Description: Size of an individual detector element, in mm. Transverse dimension followed by axial dimension. For a discrete crystal, this is the crystal size. For a continuous detector, this is the pixel bin size.
Preferred ID: DICOM:0054_1203 Type: term ID# ILX:0103143 Score: 0
Description: Model name of the detector component of the acquisition system.
Preferred ID: DICOM:0018_702B Type: term ID# ILX:0103149 Score: 0
Description: Number of active detectors used to generate a single pixel. Specified as number of row detectors per pixel then column.
Preferred ID: DICOM:0018_701A Type: term ID# ILX:0103138 Score: 0
Description: The physical configuration of the detector.
Preferred ID: DICOM:0018_7005 Type: term ID# ILX:0103140 Score: 0
Description: Specifies whether diffusion conditions for the frame are directional, or isotropic with respect to direction.
Preferred ID: DICOM:0018_9075 Type: term ID# ILX:0103235 Score: 0
Description: Coordinates (x, y, z) of common DVH normalization point in the patient based coordinate system described in (mm).
Preferred ID: DICOM:3004_0040 Type: term ID# ILX:0103608 Score: 0
Description: Mean calculated dose to ROI(s) described by DVH Referenced ROI Sequence (3004,0060).
Preferred ID: DICOM:3004_0074 Type: term ID# ILX:0103605 Score: 0
Description: Type of DVH.
Preferred ID: DICOM:3004_0001 Type: term ID# ILX:0103613 Score: 0
Description: Focal distance, in mm. A value of 0 means infinite distance for parallel collimation.
Preferred ID: DICOM:0018_1182 Type: term ID# ILX:0104340 Score: 0
Description: Number of gradient echoes collected per RF echo per shot (or excitation) per frame. A value of zero shall correspond to a pure RF echo frame. If RF Echo Train Length (0018,9240) is non zero and Gradient Echo Train Length is as well then only the central echo will be an RF Spin Echo, all others will be gradient echoes.
Preferred ID: DICOM:0018_9241 Type: term ID# ILX:0104733 Score: 0