https://www.nikoninstruments.com/en_EU/Products/Upright-Microscopes/Research/Eclipse-FN1
Fixed-stage microscope for electrophysiological research. Features include open design, noise reduction, 16x objective lens, and water dipping objective with depth induced aberration correction.
Proper citation: Nikon: Eclipse FN1 Microscope (RRID:SCR_014995) Copy
http://www.iitcinc.com/rotarod.html
Kit for assessing motor function and endurance in mice and rats. IITC’s Rotarod Test is capable of having up to five mice or rats tested at a time standard.
Proper citation: IITC Life Sciences: Rotarod Test (RRID:SCR_015698) Copy
Horizontal pipette puller to pull and polish microelectrodes from borosilicate capillaries.
Proper citation: Zeitz: DMZ Universal Electrode Puller (RRID:SCR_022056) Copy
https://biomedical-instruments.com/pdf/Narishige%20MF-830.pdf
Powerful microscope mounted to produce microelectrodes for patch clamping.
Proper citation: Narishige: MF 830 Microgrinder (RRID:SCR_022055) Copy
https://www.visualsonics.com/product/imaging-systems/vevo-3100
Vevo 3100 micro ultrasound imaging system reduces speckle noise and artifacts while preserving and enhancing critical information for small animal in vivo studies. System helps you visualize your data at high resolution.
Proper citation: Fujifilm: Vevo 3100 Imaging System (RRID:SCR_022152) Copy
Designed to eliminate complexities of microscopy, EVOS XL Core system captures high-quality brightfield cell images right at your benchtop within minute. Instrument for monitoring cell cultures, either within hood or in cell culture room.
Proper citation: Thermo Fisher: EVOS XL Core Imaging System (RRID:SCR_022190) Copy
https://jwst.nasa.gov/content/observatory/instruments/nircam.html
Instrument aboard the James Webb Space Telescope. It has two major tasks, as imager from 0.6 to 5 micron wavelength, and as wavefront sensor to keep 18-section mirrors functioning as one. Imager covers infrared wavelength range 0.6 to 5 microns. NIRCam detects light from the earliest stars and galaxies in process of formation, population of stars in nearby galaxies, as well as young stars in Milky Way and Kuiper Belt objects. NIRCam is equipped with coronagraphs, instruments that allow astronomers to take pictures of very faint objects around central bright object, like stellar systems.
Proper citation: Near Infrared Camera (RRID:SCR_022113) Copy
https://www.olympus-lifescience.com/data/olympusmicro/brochures/pdfs/ix71.pdf?rev=EABE
Research inverted system microscope. Olympus IX2 inverted microscope combined with UIS2 optical system. Used for live cell experiments.
Proper citation: Olympus: IX71 Microscope (RRID:SCR_022185) Copy
http://ced.co.uk/products/power3
Data acquisition interface from Cambridge Electronic Design Limited. Works with Spike2 to provide continuous acquisition tasks. Records waveform data, digital and marker information, and can generate waveform and digital outputs simultaneously for real-time, multi-tasking experiment control.
Proper citation: CED: Power1401 (RRID:SCR_016040) Copy
http://tools.thermofisher.com/content/sfs/manuals/nd-1000-v3.8-users-manual-8%205x11.pdf
Spectrophotometer for measurement and analysis of 1 ul samples with high accuracy and reproducibility. Full spectrum from 220nm to 750nm spectrophotometer utilizes patented sample retention technology that employs surface tension alone to hold sample in place. No need for cuvettes. Has capability to measure highly concentrated samples without dilution.
Proper citation: Thermo Fisher: Nanodrop 1000 Spectrophotometer (RRID:SCR_016517) Copy
https://www.fluigent.com/product/microfluidic-components-3/frp-flow-rate-platform/
Flow sensor for use with any flow control system. Unit to monitor flow rates in any microfluidic system with precision and accuracy.
Proper citation: Fluigent: Flow Unit (RRID:SCR_021144) Copy
https://www.fluigent.com/product/microfluidic-components-3/lineup-series-flow-ez/
System for pressure based flow control. Enables to control or monitor flow rate as well as dispense volume. When combined with LINK module capabilities are extended by using Fluigent software to benefit from automation or live monitoring and recording of data. Flow EZ modules, are available in different pressure and vacuum ranges.
Proper citation: Fluigent: Flow EZ (RRID:SCR_021145) Copy
https://www.fluigent.com/product/microfluidic-components-3/lineup-series/#Link
Provides connection of LineUp series modules to PC for software control to use Fluigent Software.
Proper citation: Fluigent: LineUp LINK (RRID:SCR_021143) Copy
https://biospherix.com/proox-c21/
Compact O2 and CO2 Subchamber Controller used together with C-Chamber Incubator Subchamber from BioSpherix or chambers from other manufacturers.
Proper citation: BioSpherix: ProOx C21 Controller (RRID:SCR_021131) Copy
https://biospherix.com/proox-360-2/
Versatile high infusion rate O2 controller.Controls Oxygen and may be used with BioSpherix C-Chamber Incubator Subchamber, C-Shuttle Glove Box, I-Glove Incubator Glove Box, Xvivo System Model X3 Cytocentric Cell Incubation and Handling Platfrom, or A-Chamber Animal Chamber. Featuring capability to infuse gas over range 1-140 SCFH, may be used together with chambers which are either home built or are available from other manufacturers.
Proper citation: BioSpherix: ProOx 360 Controller (RRID:SCR_021130) Copy
https://biospherix.com/proox-110-2/
Compact, versatile O2 controller.Controls Oxygen and may be used with either C-Chamber Incubator Subchamber or A-Chamber Animal Chamber from BioSpherix. May be used with home-built or other manufacturers chambers.
Proper citation: BioSpherix: ProOx 110 Controller (RRID:SCR_021129) Copy
https://biospherix.com/proco2-120-2/
Controls CO2 levels for most physiologic concentrations and may be connected with either C-Chamber Incubator Subchambers or A-Chamber Animal Chambers from BioSpherix. May also be connected with chambers which are either home built or are available from other manufacturers. These include thermal incubators, flush boxes, culture chambers, glove boxes, and other semi sealed enclosures.
Proper citation: BioSpherix: ProCO2 120 Controller (RRID:SCR_021127) Copy
https://biospherix.com/oxycycler-at82nn/
Provides either dynamic or static control of parts per million levels of nitric oxide (NO) and limits the undesirable elevation NO2 in animal models when used in combination with either one or two (1 or 2) A-Chamber Animal Chambers.
Proper citation: BioSpherix: OxyCycler AT82NN Controller (RRID:SCR_021188) Copy
https://biospherix.com/oxycycler-at42n/
Provides either dynamic or static control of parts per million levels of nitric oxide (NO) in animal models modeling when used in combination with either one or two (1 or 2) A-Chamber Animal Chambers.
Proper citation: BioSpherix: OxyCycler AT42N Controller (RRID:SCR_021187) Copy
https://biospherix.com/oxycycler-a42oc/
Provides either dynamic or static control of O2 and CO2 conditions for animal modeling when used in combination with one or two A-Chamber Animal Chamber(s).
Proper citation: BioSpherix: OxyCycler A42OC Controller (RRID:SCR_021183) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the NIF Resources search. From here you can search through a compilation of resources used by NIF and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that NIF has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on NIF then you can log in from here to get additional features in NIF such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into NIF you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within NIF that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.