Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.
https://www.labconco.com/product/refrigerated-centrivap-vacuum-concentrators/74
Refrigerated centrifugal concentrator that concentrates heat sensitive samples using centrifugal force, vacuum, and controlled temperature. Concentrator has heater and refrigeration systems have temperature range of negative 4 C to 100 C.
Proper citation: Labconco: CentriVap Refrigerated Centrifugal Concentrator (RRID:SCR_018587) Copy
https://usa.jpk.com/products/automated-force-spectroscopy/forcerobot-300
Force spectroscope that automates routine procedures, data acquisition and evaluation. Force curves without events are filtered out before processing.
Proper citation: JPK Instruments: 300 Force Robot Automated Force Spectroscope (RRID:SCR_018586) Copy
Microplate reader with top and bottom read capability with dual monochromators for fluorescence intensity assays using multiple point well scanning. Temperature sensitive reactions are from ambient to 45 C. Measures fluorescence on variety of sample formats from 6 to 384 well microplates in endpoint, kinetic, spectral scan, and well-scan modes.
Proper citation: Molecular Devices: Gemini EM Microplate Reader (RRID:SCR_018584) Copy
https://www.konnis.com/products/instruments-for-sale/hamilton-starlet-liquid-handling-system/
Liquid handling robot with 8 channel pipetting arm, dual HEPA filter top, and 96 channel pipeting head with 1ml capacity. It can have tube racks, microplate racks, and 50mL temperature controlled tube rack.
Proper citation: Hamilton: StarPlus Automated Liquid Handler (RRID:SCR_018582) Copy
https://www.thermofisher.com/order/catalog/product/4406016#/4406016
Applied Biosystems 3500xL 24-capillary Genetic Analyzer is used for the Human Identification application.Genetic analyzer that utilizes capillary electrophoresis for genetic analysis. It has capillary lengths of 50 cm or 36 cm and can use 384 well plates or 96 well plates.
Proper citation: Thermo Fisher: Applied Biosystems: 3500xl Genetic Analyzer (RRID:SCR_018438) Copy
https://www.labx.com/product/applied-biosystems-3700
Automated capillary gel electrophoresis genetic analyzer that sequences up to 96 DNA templates per run and is used for PCR sequencing and short tandem repeat genotyping.
Proper citation: Thermo Fisher: Applied Biosystems: ABI 3700 Genetic Analyzer (RRID:SCR_018431) Copy
https://www.labx.com/product/applied-biosystems-3100
Benchtop capillary genetic analyzer multicolor fluorescence based DNA analysis system with 16 capillaries. It can process 96 or 384 well plates.
Proper citation: Thermo Fisher: Applied Biosystems: ABI 3100 Capillary Genetic Analyzer (RRID:SCR_018430) Copy
Microplate reader that can read one sample or up to 384 in single plate read using any standard cuvette, 12 x 75 mm test tube, or 96 or 384 well microplate. It can run standard spectrophotometer and microplate reader applications.
Proper citation: Molecular Devices: Spectramax Plus384 Microplate Reader (RRID:SCR_018598) Copy
https://www.milabs.com/u-spect/
Nuclear imager for quantitative 3D functional imaging of SPECT tracers down to 0.12 mm ex vivo and 0.25 mm in vivo. Used for quantitative sub mm imaging of higher energy and theranostic isotopes such as 131I, 188Re, 213Bi, 225Ac, and 223Ra.
Proper citation: MILabs: U Spect Nuclear Imager (RRID:SCR_018597) Copy
Isothermal titration calorimeter for label free, in solution, study of biomolecular interactions. It delivers measurement of binding parameters with minimum of 10 ug sample.
Proper citation: Malvern Panalytical: Microcal ITC 200 Isothermal Titration Calorimeter (RRID:SCR_018590) Copy
Benchtop manager cell sorter for cell isolation in automated workflows. Sorts cells directly from whole blood or bone marrow without density gradient centrifugation or erythrocyte lysis.
Proper citation: Miltenyi: AutoMACS Magnetic Cell Sorter (RRID:SCR_018596) Copy
https://ctac.mbi.ufl.edu/histology-self-serve/microm-cryostat/
Electronic microtome cryostat upright standing with open top working area that can cut temperature to negative 35 degrees Celsius. Equipped with automatic 24 hour defroster with interrupt key and handwheel brake.Provides protection for knife and specimen as it retracts specimen at the end of the cut. Motorized coarse feed system allows sample to be moved forward and backward.Two knife carriers are available. Standard knife carrier is for knives to be easily clamped in place and adjusted, and the disposable blade holder EC for high- and low-profile blades.
Proper citation: Microm: HM505E Cryostat (RRID:SCR_018595) Copy
Differential scanning calorimeter for study of samples in solution. It measures intramolecular stability of proteins, nucleic acids, oligomeric proteins, nucleic acid duplexes, lipid and detergent micellar system.
Proper citation: Malvern Panalytical: Microcal VPViewerTM Differential Scanning Calorimeter VP--DSC (RRID:SCR_018594) Copy
https://www.perkinelmer.com/Product/ht-labchip-gx-ii-touch-cls138160
LabChip GXII Touch is a protein characterization system that provides reproducible quantitation, molecular weight sizing and percent purity analysis of protein samples. Leveraging microfluidic electrophoretic separation technology, the LabChip GXII Touch system enables rapid characterization with minimal sample preparation setup and sample input volume.
Proper citation: Illumina: LabChip GXII Touch protein characterization system (RRID:SCR_018593) Copy
https://docs.research.missouri.edu/emc/Pelco-Biowave-user-manual.pdf
Laboratory microwave system that includes True Variable Wattage, water recirculation system, temperature restrictive temperature probe, RS232 Port, Cable and Software, Programmable times, Four intermittent power settings, Magnetron prewarming, Air Bubbler, and Vacuum Cycling. System has precision temperature control and monitoring for microwave assisted processing of tissue. Can be used for formalin fixation, decalcification, special stains, immunocytochemistry and complete processing of tissue into paraffin.
Proper citation: SelectScience: PELCO BioWave 34700 laboratory microwave system (RRID:SCR_018608) Copy
https://www.olympusamerica.com/cpg_section/cpg_archived_product_details.asp?id=1252
Intravital laser scanning microscope for small animal imaging with up to four lasers 488nm, 561nm, 633nm, and 748nm. Able to image multiple fluorescence probes simultaneously. Scan head has tilting capability to image objective orientation in three dimensions.Three magnifications of MicroProbe lenses enable to capture either large field of view or high resolution images on living animal. Certain conventional microscope objectives can also be used on IV100 as well.
Proper citation: Olympus: IV-100 Intravital Laser Scanning Microscope (RRID:SCR_018607) Copy
https://www.perkinelmer.com/product/titan-mps-16-position-sys-230v-50-60hz-n3130100
Microwave sample preparation device system designed to count and size particles individually. It can used for in service oil samples with only 4 mL of 10 times diluted samples.
Proper citation: Perkin Elmer: Titan MPS 16 Position Microwave Sample Preparation Device (RRID:SCR_018611) Copy
https://www.perkinelmer.com/CMSResources/Images/46-73886SPC_TriCarb2910TRLSA.pdf
Benchtop liquid scintillation analyzer that detects small amounts of alpha, beta, and gamma radioactivity. Time resolved liquid scintillation counting is used for low background counting of LS samples., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Proper citation: Perkin Elmer: Packard Tri-Carb 2900TR Liquid Scintillation Analyzer (RRID:SCR_018610) Copy
https://mass-spec.stanford.edu/instruments
Scion GC triple quad is applied to targeted trace level analysis of metabolites and other small molecules. Electron ionization combines with MS/MS capability for outstanding selectivity. Samples are often derivatized for compatibility with GC/MS.
Proper citation: Bruker: Scion TQ GC/MS mass spectrometer (RRID:SCR_018698) Copy
https://mass-spec.stanford.edu/instruments
Bruker micrOTOF-Q II is benchtop Q-Tof mass spectrometer, applied to applications such as small molecule accurate mass determination, intact protein analysis including antibodies, peptide mapping, and other custom projects. This system is operated with Agilent 1260 UPLC and includes inline diode array detector and ESI source.
Proper citation: Bruker: micrOTOF-Q II LC/MS system (RRID:SCR_018697) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the NIF Resources search. From here you can search through a compilation of resources used by NIF and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that NIF has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on NIF then you can log in from here to get additional features in NIF such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into NIF you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within NIF that you can filter your data on
Here are the subcategories present within this category that you can filter your data on