Searching across hundreds of databases

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

Resource Name
Ugo Basile Dynamic Plantar Aesthesiometer
RRID:SCR_021751 RRID Copied      
PDF Report How to cite
Ugo Basile Dynamic Plantar Aesthesiometer (RRID:SCR_021751)
Copy Citation Copied
Resource Information

URL: https://www.ugobasile.com/products/catalogue/pain-and-inflammation/dynamic-plantar-aesthesiometer-electronic-von-frey

Proper Citation: Ugo Basile Dynamic Plantar Aesthesiometer (RRID:SCR_021751)

Description: Aesthesiometer for mechanical stimulation Model 37550. Instrument designed to automate assessment of touch sensitivity on plantar surface of rats or mice and comes ready with all necessary accessories. At each paw withdrawal, automatically detects and records latency time, and actual force at time of paw withdrawal reflex. Movable force actuator is positioned below plantar surface of animal and desired force and force speed is applied, as preset by operator. Von Frey type 0.5mm rigid filament exerts increasing force, until animal twitches its paw.

Abbreviations: DPA

Synonyms: Electronic Von Frey, Dynamic Plantar Aesthesiometer for mechanical stimulation Model 37550, Ugo Basile Dynamic Plantar Aesthesiometer, Plantar Von Frey instrument

Resource Type: instrument resource

Keywords: Instrument, equipment, USEDit, mechanical stimulation, touch sensitivity, automated assessment

Expand All
This resource

is listed by

USEDit

Usage and Citation Metrics

We found {{ ctrl2.mentions.total_count }} mentions in open access literature.

We have not found any literature mentions for this resource.

We are searching literature mentions for this resource.

Most recent articles:

{{ mention._source.dc.creators[0].familyName }} {{ mention._source.dc.creators[0].initials }}, et al. ({{ mention._source.dc.publicationYear }}) {{ mention._source.dc.title }} {{ mention._source.dc.publishers[0].name }}, {{ mention._source.dc.publishers[0].volume }}({{ mention._source.dc.publishers[0].issue }}), {{ mention._source.dc.publishers[0].pagination }}. (PMID:{{ mention._id.replace('PMID:', '') }})

Checkfor all resource mentions.

Collaborator Network

A list of researchers who have used the resource and an author search tool

Find mentions based on location


{{ ctrl2.mentions.errors.location }}

A list of researchers who have used the resource and an author search tool. This is available for resources that have literature mentions.

Ratings and Alerts

No rating or validation information has been found for Ugo Basile Dynamic Plantar Aesthesiometer.

No alerts have been found for Ugo Basile Dynamic Plantar Aesthesiometer.

Data and Source Information